Impact of Current Density on Wire Bond Lifetime – Power Cycle Testing with Clamped VCE for Realistic Current Stress

Konferenz: PCIM Europe 2023 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
09.05.2023-11.05.2023 in Nürnberg, Germany

doi:10.30420/566091006

Tagungsband: PCIM Europe 2023

Seiten: 10Sprache: EnglischTyp: PDF

Autoren:
Schmidt, Ralf; Endres, Michael (Siemens AG, Germany)
Sippel, Marcel (Siemens AG, Germany & Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany)

Inhalt:
Power cycle testing is the established method to assess IGBT modules’ lifetime. In a highly accelerated test, the end-of-life failure modes are provoked by repetitive DC current pulses. However, in real-life inverter operation a big portion of the power losses is produced by switching events and much smaller current densities are present in the module. Especially the wire bond lifetime depends on the current density and exaggerated test load currents can lead to early wire bond lift-off. This article presents experimental results on the impact of current density on wire bond lifetime and introduces a novel power cycling test method that allows for testing with moderate currents.