Advantages of Rogowski Coil over Desaturation Method for Leg Short Circuit Detection in Inverters

Konferenz: PCIM Europe 2022 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
10.05.2022 - 12.05.2022 in Nürnberg, Germany

doi:10.30420/565822159

Tagungsband: PCIM Europe 2022

Seiten: 6Sprache: EnglischTyp: PDF

Autoren:
Mutlu, Ali (Akim Metal, Turkey & Istanbul Technical University, Department of Electrical Engineering, Turkey)
Yildirim, Deniz (Istanbul Technical University, Department of Electrical Engineering, Turkey)
Kueruem, B. Avni (Turkish-German University, Department of Electrical-Electronics Engineering, Turkey)

Inhalt:
Leg short circuit detection is inconvenient to implement in IGBT modules due to its physical structure. There are several different solutions to detect overcurrent for inverters but this paper analyzes and discusses the most common ones. Inadvertent tripping can occur in a short circuit detection method using desaturation for premium motor drives with the excessive dynamic operation. Current flowing through the IGBTs can be measured using a Rogowski Coil where the flow of time-varying current in the center of the coil results in an induced voltage in which integration gives current waveform. The Rogowski Coil method can be easily implemented into the current path and its output has a high response time due to the absence of a magnetic core. This paper discusses the advantages of using the Rogowski Coil over desaturation method in leg short circuit current detection. Experimental results show that the Rogowski Coil method can detect leg short circuit with a small time delay which is mainly caused by response times of operational amplifier and comparator. Implementing Rogowski Coil structure on printed-circuit board occupies less space and results in low cost compact solution.