Estimating Auxiliary Power Supply Consumption of the Modular Multilevel Converter Submodule for the Condition Health Monitoring

Konferenz: PCIM Europe 2022 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
10.05.2022 - 12.05.2022 in Nürnberg, Germany

doi:10.30420/565822068

Tagungsband: PCIM Europe 2022

Seiten: 9Sprache: EnglischTyp: PDF

Autoren:
Lobos, Ignacio Polanco; Dujic, Drazen (Ecole Polytechnique Federale du Lausanne, EPFL, Power Electronics Laboratory, Switzerland)

Inhalt:
Condition health monitoring strategies applied to different power electronics applications are gaining popularity as early component degradation detection can trigger preventive maintenance actions before a significant fault occurs. In highly modular converter structures, such as the modular multilevel converters, made out of many submodules, the development and implementation of condition health monitoring strategies are significant and challenging. This paper analyzes and demonstrates the use of the auxiliary submodule power supply consumption to recognize submodule sub-circuits abnormal operation. Thus, a new strategy to monitor submodules components is provided, enabling new prospective condition health monitoring methods locally or at the converter level. Experimental results show the effectiveness of the proposed idea.