Sensorless Control of a Bridgeless PFC Using a Low Pass Filter Model and a Linear PR Controller
Konferenz: PCIM Europe 2017 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
16.05.2017 - 18.05.2017 in Nürnberg, Deutschland
Tagungsband: PCIM Europe 2017
Seiten: 6Sprache: EnglischTyp: PDF
Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt
Autoren:
Lopez, Felipe; Lamo, Paula; Azcondo, Francisco; Pigazo, Alberto (University of Cantabria, Spain)
Inhalt:
Compared with traditional power factor correction, PFC, converters, Bridgeless PFC reduces the conduction losses since the power conversion is carried out by only one stage. However, the measurement of the grid voltage and current become differential, increasing the cost and the circuit complexity. This paper proposes a solution that avoids the use of the sensor of the input current. Instead, the current is rebuilt inside a digital device (FPGA) by low-pass filtering the estimated voltage across the input inductor over time.