A method to evaluate IGBT module losses on system level
Konferenz: PCIM Asia 2016 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
28.06.2016 - 30.06.2016 in Shanghai, China
Tagungsband: PCIM Asia 2016
Seiten: 5Sprache: EnglischTyp: PDF
Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt
Autoren:
Shen, Song; Ziqing, Zheng (Infineon Technologies China Co., Ltd., China)
Ruicheng, Yang; Chao, Mu (Shenzhen Inovance Technology Co., Ltd., China)
Inhalt:
IGBT module switching losses are typically calculated based on datasheet values instead of employing a direct measurement method on components of the real system. These calculated losses may be far away from the module’s losses in the real system. By applying an experimental method that drives IGBT modules using the system’s driver board and busbar, losses can be derived with little effort utilizing the real system in its operating environment.