A robust and automated parameters calibration procedure for PSpice IGBT models

Konferenz: PCIM Europe 2014 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
20.05.2014 - 22.05.2014 in Nürnberg, Deutschland

Tagungsband: PCIM Europe 2014

Seiten: 8Sprache: EnglischTyp: PDF

Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt

Autoren:
Cavaiuolo, D.; Riccio, M.; Maresca, L.; Falco, G. De; Romano, G.; Irace, A.; Breglio, G. (Dept. of Electrical Engineering and Information Technologies, University Federico II, Via Claudio 21, 80125 Naples, Italy)

Inhalt:
In this work an automated calibration procedure for PSpice IGBT models is presented. The proposed solution is based on an best-fitting approach with a parameter-to-curve differential coefficients estimation, able to evaluate a reduced set of parameters for the static and dynamic simulations. The effectiveness of the procedure is proven applying it to the standard IGBT Hefner model for a 600V PT-trench IGBT. Model parameters have been extracted and calibrated by using experimental data. Finally the reliability of the procedure is proven in a buck-converter application, where the IGBT power losses and circuit efficiency are evaluated.