Evaluation of the thermal contact resistance between bulk copper and metal foam using transient measurements
Konferenz: CIPS 2022 - 12th International Conference on Integrated Power Electronics Systems
15.03.2022 - 17.03.2022 in Berlin, Germany
Tagungsband: ETG-Fb. 165: CIPS 2022
Seiten: 6Sprache: EnglischTyp: PDF
Autoren:
Janod, Goulven (Univ. Grenoble Alpes, CNRS, Grenoble INP, G2Elab, SIMAP, Grenoble, France)
Avenas, Yvan (Univ. Grenoble Alpes, CNRS, Grenoble INP, G2Elab, Grenoble, France)
Bouvard, Didier (Univ. Grenoble Alpes, CNRS, Grenoble INP, SIMAP, Grenoble, France)
Khazaka, Rabih (Safran SA, Safran Tech, Chateaufort, CS 80112, France)
Inhalt:
One of the most important issues in power electronics is the heat dissipation. A fluid flowing in a metal foam seems to be an efficient way to achieve it. However, the contact material between the metal foam and the device may have a great influence on the thermal behavior of the system and its thermal resistance therefore needs to be evaluated. A new method, developed for this purpose and based on thermal transient measurements is presented in this article and compared with a more conventional steady state method. Results show that the two methods are globally in accordance, even if transient measurements seem to underestimate thermal contact resistance.