Integrated High-Temperature Isolation barrier with Coreless Transformer

Konferenz: CIPS 2016 - 9th International Conference on Integrated Power Electronics Systems
08.03.2016 - 10.03.2016 in Nürnberg, Deutschland

Tagungsband: CIPS 2016

Seiten: 4Sprache: EnglischTyp: PDF

Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt

Autoren:
Perrin, Remi; Allard, Bruno; Martin, Christian; Buttay, Cyril (Université de Lyon, Ampere, INSA de Lyon, UCB Lyon 1, Lyon, France)

Inhalt:
A novel coreless technology based on an existing process but initially designed to produce integrated passive components for commercial temperatures, is used and its capability at 200 C is tested. Design aspects and electrical characterizations of the samples are presented. An endurance test, realized with a full modulation and demodulation prototype board, shows a satisfactory behaviour at high temperatures. Finally, a dynamic isolation test checks the coreless transformer behaviour against dV/dt perturbation. This work targets a high-temperature inverter application with high-frequency switching frequency and based on multi-chip module.