Cover IEC 60601-2-21:2020
größer

IEC 60601-2-21:2020

Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers

Ausgabedatum: 2020-09
Edition: 3.0
Sprache: EN-FR - zweisprachig englisch/französisch
Seitenzahl: 77 VDE-Artnr.: 249195

Inhaltsverzeichnis

IEC 60601-2-21:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. IEC 60601-2-21:2020 specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
This particular standard does not apply to:
- devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;
- INFANT INCUBATORS; for information, see IEC 60601-2-19;
- INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20;
- INFANT PHOTOTHERAPY EQUIPMENT, for information, see IEC 60601-2-50.
SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED RADIANT WARMER including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56. IEC 60601-2-21:2020 cancels and replaces the second edition published in 2009 and Amendment 1:2016. This edition constitutes a technical revision. IEC 60601-2-21:2020 includes the following significant technical change with respect to the previous edition: alignment with IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.

Buchtitel Format
Entwicklung und Herstellung medizinischer Software
Prinz, Thorsten (Hrsg.)

Entwicklung und Herstellung medizinischer Software

Normen in der Medizintechnik
VDE-Schriftenreihe – Normen verständlich, Band 171

2017, 219 Seiten, Din A5, Broschur

Dieser Buchtitel ist auch als E-Book (PDF) erhältlich
Fachbuch eBook (PDF) Kombi-Fassung - Buch und E-Book