Cover IEC 60601-1-9:2007
größer

IEC 60601-1-9:2007

Medical electrical equipment - Part 1-9: General requirements for basic safety and essential performance - Collateral Standard: Requirements for environmentally conscious design

Ausgabedatum: 2007-07
Edition: 1.0
Sprache: EN-FR - zweisprachig englisch/französisch
Seitenzahl: 60 VDE-Artnr.: 213572

Inhaltsverzeichnis

IEC 60601-1-9:2007 The objective of this collateral standard is to improve the environmental impact for the entire range of medical electrical equipment, taking into account all stages of the product life cycle:
- product specification;
- design;
- manufacturing;
- sales, logistics, installation;
- use;
- end of life management. This means protecting the environment and human health from hazardous substances, conserving raw materials and energy, minimizing the generation of waste, as well as minimizing the adverse environmental impacts associated with waste. The criteria needed to reach this goal must be integrated into all stages of the medical electrical equipment life cycle from the specification stage to end of life management. The environmental impacts of me equipment through all life-cycle stages are determined from the medical electrical equipment's environmental aspects defined during the identification of need, product planning, and design stages. Consideration of environmental aspects as early as possible in these stages can produce numerous benefits that might include lower costs, stimulation of innovation and creativity, and increased knowledge about the product. It can also provide new business opportunities, and improved product quality as well as reduction of adverse environmental impacts. The assessment of the environmental aspects and impacts of medical electrical equipment is a developing science and it is anticipated that this collateral standard will require periodic updating as the science develops. The requirements given in this collateral standard do not replace national or international laws and regulations. Environmental protection is one element of the overall risk management process as required by the general standard. The acceptability of medical electrical equipment's environmental impacts are balanced against other factors, such as the product's intended function, performance, safety, cost, marketability, quality, legal and regulatory requirements. This balance can differ depending on the intended function of the medical electrical equipment. For example, a solution appropriate for life-saving or life-supporting medical electrical equipment might not be appropriate for a device intended to correct a minor ailment. A manufacturer of medical electrical equipment might have to justify, as a result of risk management, that a medical benefit outweighs the associated adverse environmental impacts.

Buchtitel Format
Elektrische Sicherheit in medizinisch genutzten Bereichen
Hofheinz, Wolfgang

Elektrische Sicherheit in medizinisch genutzten Bereichen

Normgerechte Stromversorgung und fachgerechte Überprüfung medizinischer elektrischer Geräte; DIN VDE 0100-100, DIN VDE 0100-410, DIN VDE 0100- 710, DIN IEC/TS 60479-1 (VDE V 0140-479-1), DIN VDE 0701-0702, DIN EN 60601-1 (VDE 0750-1), DIN EN 61140 (VDE 0140-1), DIN EN 61557-8 (VDE 0413-8), DIN EN 61557-9 (VDE 0413-9), DIN EN 62353 (VDE 0751-1)
VDE-Schriftenreihe – Normen verständlich, Band 117

2018, 187 Seiten, Din A5, Broschur

Dieser Buchtitel ist auch als E-Book (PDF) erhältlich
Fachbuch eBook (PDF) Kombi-Fassung - Buch und E-Book
Entwicklung und Herstellung medizinischer Software
Prinz, Thorsten (Hrsg.)

Entwicklung und Herstellung medizinischer Software

Normen in der Medizintechnik
VDE-Schriftenreihe – Normen verständlich, Band 171

2017, 219 Seiten, Din A5, Broschur

Dieser Buchtitel ist auch als E-Book (PDF) erhältlich
Fachbuch eBook (PDF) Kombi-Fassung - Buch und E-Book