Compensation Techniques for Bandwidth-Distorted Measurements of Fast Transients in Double Pulse Tests
Conference: PCIM Europe 2024 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
06/11/2024 - 06/13/2024 at Nürnberg, Germany
doi:10.30420/566262471
Proceedings: PCIM Europe 2024
Pages: 6Language: englishTyp: PDF
Authors:
Lottis, Christian; Sprunck, Sebastian; Sah, Bikash; Jung, Marco
Abstract:
While assessing the losses in Wide-Bandgap (WBG) devices in a Double-Pulse-Test (DPT), stringent requirements for high-fidelity probes have to be applied. The limited bandwidth of a probe has a significant influence on the measurement results due to its inherent delay and distortion effects that originate from its parasitic or discrete filter components. This paper proposes a technique to compensate for these influences by post-processing measured data based on the characteristics of the used probes. Instead of using a complex inverse transfer function of the probe, an average error compensation is developed and discussed for use in a DPT and validated based on circuit simulation.