Characterization of Power-Module Parasitics: Sub-Nanosecond Large Signal Pulsing vs. Double-Pulse Testing
Conference: PCIM Europe 2024 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
06/11/2024 - 06/13/2024 at Nürnberg, Germany
doi:10.30420/566262122
Proceedings: PCIM Europe 2024
Pages: 11Language: englishTyp: PDF
Authors:
Helmut, Dennis; Gesele, Felix; Brueckner, Thomas; Groos, Gerhard
Abstract:
This paper compares the novel sensor gap transmission line pulsing (sgTLP) technique with the established method of double-pulse testing (DPT) for characterizing parasitic inductances in a fast SiC halfbridge power module. SgTLP employs Transmission Line Pulsing with its sub-nanosecond temporal resolution and voltages up to 2 kV to detect parasitic inductances and capacitive effects, which are not typically observable with DPT. While both, sgTLP and established methods, produce corresponding results for the total inductances, sgTLP additionally offers a deeper insight into the structure of the module’s internal inductive and even capacitive network.