An Approach to Online Wear Out Monitoring of PCB Interconnects in Safety-Critical Systems

Conference: SMACD / PRIME 2021 - International Conference on SMACD and 16th Conference on PRIME
07/19/2021 - 07/22/2021 at online

Proceedings: SMACD / PRIME 2021

Pages: 4Language: englishTyp: PDF

Authors:
Yazdani, Saeid; Wolz, Werner; Schott, Christian; Heinkel, Ulrich (Dept. of ETIT, TU Chemnitz, Chemnitz, Germany)
Engelhardt, Rainer (Steinbeis Center of Design and Test, Steinbeis GmbH, Chemnitz, Germany)
Kriesten, Daniel (Dept. of Engineering, HS Mittweida, Mittweida, Germany)

Abstract:
Online monitoring inside electronic control units (ECU) is mandatory for all safety-critical systems. Dedicated quality and safety monitoring structures will be described that support the early detection of health problems. Interconnect wear-out and delamination are major failure causes in printed circuit boards, and sensitive detector arrangements allow for the estimation of near-future fail situations. Countermeasures like pre-emptive service actions can keep the system safe without running into emergency situations (i.e. activating redundancy), and the number of system emergency states can be reduced. This paper suggests methods for online monitoring of wear-out detectors to increase reliability and safety.