Cover IEC 62439-7:2011
größer

IEC 62439-7:2011

Industrial communication networks - High availability automation networks - Part 7: Ring-based Redundancy Protocol (RRP)

Circulation Date: 2011-12
Edition: 1.0
Language: EN-FR - bilingual english/french
Seitenzahl: 172 VDE Artno.: 218509

Content

IEC 62439-7:2011 specifies a redundancy protocol that is based on a ring topology, in which the redundancy protocol is executed at the end nodes, as opposed to being built into the switches. Each node detects link failure and link establishment using media-sensing technologies, and shares the link information with the other nodes, to guarantee fast connectivity recovery times. The nodes have equal RRP network management functions.

This publication is to be read in conjunction with IEC 62439-1:2010. The contents of the corrigendum of May 2015 have been included in this copy.